HJ/T 36-1999標(biāo)準(zhǔn)中,使用GDX-502填充柱(3m×4mm, 60-80目),采用直接進(jìn)樣-氣相色譜法(FID檢測(cè)器) 是測(cè)定固定污染源排氣中丙烯醛的經(jīng)典方法
這個(gè)方法適用于固定污染源有組織排放(如煙囪、排氣筒)和無(wú)組織排放(如廠(chǎng)界無(wú)組織逸散)的丙烯醛測(cè)定。
方法原理:排氣中的丙烯醛(CH?CHCHO)樣品直接注射進(jìn)入氣相色譜儀,經(jīng)GDX-502色譜柱分離后,用氫火焰離子化檢測(cè)器(FID) 進(jìn)行檢測(cè)。通過(guò)對(duì)比標(biāo)準(zhǔn)樣品色譜峰的保留時(shí)間進(jìn)行定性分析,利用峰高(或峰面積)進(jìn)行定量分析1。
方法性能:該方法的檢出限為0.1 mg/m³。當(dāng)進(jìn)樣體積為1毫升時(shí),定量測(cè)定范圍一般為0.31 mg/m³ ~ 100.0 mg/m³
浩瀚色譜(山東)應(yīng)用技術(shù)開(kāi)發(fā)有限公司,采用固定污染源中丙xi醛的測(cè)定GDX502玻璃色譜柱測(cè)定固定污染源排氣中丙xi醛,面積外標(biāo)法定量,在安捷倫,島津,賽默飛,瓦里安,布魯克,PE上安裝使用,效果良好。
名稱(chēng):硬質(zhì)玻璃柱
規(guī)格:3m*4mm
型號(hào):GDX-502,60/80目
應(yīng)用:HJ/T 36-1999 固定污染源排氣中丙xi醛的測(cè)定 氣相色譜法
適用于:
安捷倫490在線(xiàn)/便攜,4890,5890,6890,7820,7890,8860,8890
島津GC-14C,GC-2010,GC-2014,GC-2030
賽默飛1310,1300,1610,1600
瓦里安3800系列
布魯克PE580,590,680,690
磐諾A90,福立GC9790,華愛(ài),天瑞,天美,GC7900,川儀,北分瑞利,東西電子,魯南瑞虹,捷島/科曉



In the HJ/T 36-1999 standard, the use of GDX-502 packed column (3m × 4mm, 60-80 mesh) and direct injection gas chromatography (FID detector) is a classic method for determining acrolein in exhaust gas from fixed pollution sources
This method is applicable for the determination of acrolein in organized emissions (such as chimneys and exhaust pipes) and unorganized emissions (such as unorganized emissions at the factory boundary) from fixed pollution sources.
Method principle: The sample of acrolein (CH ? CHCHO) in the exhaust is directly injected into the gas chromatograph, separated by the GDX-502 chromatographic column, and detected using a hydrogen flame ionization detector (FID). Qualitative analysis is performed by comparing the retention time of chromatographic peaks of standard samples, and quantitative analysis is performed using peak height (or peak area).
Method performance: The detection limit of this method is 0.1 mg/m ³. When the injection volume is 1 milliliter, the quantitative determination range is generally between 0.31 mg/m ³ and 100.0 mg/m ³
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. uses GDX502 glass chromatography column to determine formaldehyde in exhaust gas from fixed pollution sources, and uses area external standard method for quantification. It has been installed and used on Agilent, Shimadzu, Thermo Fisher, Varian, Brooke, and PE with good results.
Name: Hard Glass Column
Specification: 3m * 4mm
Model: GDX-502, 60/80 mesh
Application: HJ/T 36-1999 Determination of Propionaldehyde in Fixed Source Exhaust Gas by Gas Chromatography
Suitable for:
Agilent 490 online/portable, 48905890689088608890
Shimadzu GC-14C, GC-2010, GC-2014, GC-2030
Thermo Fisher Scientific 1310130016101600
Varian 3800 Series
Brooke PE580590680690
Panno A90, Fuli GC9790, Huaai, Tianrui, Tianmei, GC7900, Chuanyi, Beifen Ruili, Dongxi Electronics, Lunan Ruihong, Jiedao/Kexiao